Skip to main content

HS.FHIR.vSTU3.Model.Base.Reference

deprecated class HS.FHIR.vSTU3.Model.Base.Reference extends HS.FHIR.vSTU3.Model.Base.Element

THIS DATA OBJECT MODEL CLASS IS DEPRECATED - Use %DynamicObject or HS.FHIRObject.* instead.
A reference from one resource to another.
If the element is present, it must have a value for at least one of the defined elements, an @id referenced from the Narrative, or extensions

Property Inventory

Method Inventory

Parameters

parameter ELEMENTQUALIFIED = 1;
Inherited description: ELEMENTQUALIFIED controls the format of exported XML. The ELEMENTQUALIFIED specification should be based on the elementFormDefault attribute of the schema that defines the type. To maintain compatibility, ELEMENTQUALIFIED will default to 1 (true) for literal format export and will default to 0 (false) for encoded or encoded12 format export. These were the values always previously assumed for the elementFormDefault attribute.

NOTE: Direct use of XMLExport method does not support the ELEMENTQUALIFIED. The export must be done using %XML.Writer or SOAP support.

parameter JSONTYPEFIELD;
Inherited description: Type property name for JSON export.
parameter XMLNAME = Reference;
Inherited description: This parameter provides the default XMLNAME for the class. If it is empty then the class name will be used to construct a default XML name. The default XMLNAME is used as the top level tag when exporting objects and the export context did not provide an XML container name.
parameter XMLSEQUENCE = 1;
Inherited description: If the XMLSEQUENCE = 1, then the order of the XML elements must match the order of the class properties. This allows us to deal with XML where the same field appears multiple times and is distinguished by the order.

Properties

property display as HS.FHIR.vSTU3.Model.Datatype.String (XMLNAME = "display", XMLPROJECTION = "ELEMENT");
Plain text narrative that identifies the resource in addition to the resource reference.
Property methods: displayGet(), displayGetSwizzled(), displayIsValid(), displayNewObject(), displaySet()
property identifier as HS.FHIR.vSTU3.Model.Base.Identifier (XMLNAME = "identifier", XMLPROJECTION = "ELEMENT");
An identifier for the other resource. This is used when there is no way to reference the other resource directly, either because the entity is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference.
Property methods: identifierGet(), identifierGetSwizzled(), identifierIsValid(), identifierNewObject(), identifierSet()
property reference as HS.FHIR.vSTU3.Model.Datatype.String (XMLNAME = "reference", XMLPROJECTION = "ELEMENT");
A reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources.
Property methods: referenceGet(), referenceGetSwizzled(), referenceIsValid(), referenceNewObject(), referenceSet()

Methods

deprecated method %OnNew(pReference As %String, pDisplay As %String, pExtension As %RegisteredObject) as %Status
THIS DATA OBJECT MODEL CLASS IS DEPRECATED - Use %DynamicObject or HS.FHIRObject.* instead.
Get new object, populated with specified data.
deprecated method SetDisplay(pValue As %String = "", pExtension As %RegisteredObject = "", pId As %String = "") as %Status
THIS DATA OBJECT MODEL CLASS IS DEPRECATED - Use %DynamicObject or HS.FHIRObject.* instead.
Set method for the "display" property.
deprecated method SetIdentifier(pValue As %String = "", pSystem As %String = "", pUse As %String = "", pTypeCode As %String = "", pTypeSystem As %String = "", pTypeDisplay As %String = "", pTypeText As %String = "", pId As %String = "", pStart As %String = "", pEnd As %String = "", pAssignerReference As %String = "", pAssignerDisplay As %String = "", pExtension As %RegisteredObject = "") as %Status
THIS DATA OBJECT MODEL CLASS IS DEPRECATED - Use %DynamicObject or HS.FHIRObject.* instead.
Set method for the "identifier" property.
deprecated method SetReference(pValue As %String = "", pExtension As %RegisteredObject = "", pId As %String = "") as %Status
THIS DATA OBJECT MODEL CLASS IS DEPRECATED - Use %DynamicObject or HS.FHIRObject.* instead.
Set method for the "reference" property.

Inherited Members

Inherited Properties

Inherited Methods

FeedbackOpens in a new tab