Enable/disable the <MAXNUMBER> error on numeric overflow.
Synopsis
[Miscellaneous]    TruncateOverflow=n
Description
Normally, when InterSystems IRIS encounters a number larger than 9223372036854775807 E127 (or smaller than -9223372036854775808 E127) it throws the <MAXNUMBER> error. You can prevent this with the TruncateOverflow setting. The value n may be 1 or 0:
Examples
TruncateOverflow=0
Range of Values
0 or 1. The default is 0.
Management Portal
On the page System Administration > Configuration > Additional Settings > Compatibility, in the TruncateOverflow row, select Edit. Choose true (selected) or false (cleared).